Reverse osmosis elements

Three RO families in the 2025 manual: seawater SY-SW, brackish SY-BW, and ultra-low-pressure SY-ULP. Each family has its own model table.

Reverse osmosis skid RO-01 with Shuiyan pressure vessels

SY-SW seawater elements

SY-SW seawater elements
ModelAverage fluxStable desalinationEffective areaFeed screen
SY-SW4040-HR1,450 GPD99.8%85 ft² (8 m²)28 mil
SY-SW8040-HF(400)9,000 GPD99.8%400 ft² (37 m²)34 mil
SY-SW8040-HF(440)9,900 GPD99.8%440 ft² (41 m²)28 mil
SY-SW8040-HR(400)7,000 GPD99.8%400 ft² (37 m²)34 mil
SY-SW8040-HR(440)7,700 GPD99.8%440 ft² (41 m²)28 mil
SY-SW8040-HPZ(400)8,500 GPD99.7%400 ft² (37 m²)34 mil

Test: 25°C (77°F), 32,000 ppm NaCl, 800 psi (5.52 MPa), recovery 8%, pH 7.5–8.0. Test-condition flux is the manual’s average permeate flow for that element. Allowable variation on a single element is ±15%.

SY-SW maximum operating values

SY-SW maximum operating values
LimitValueLimitValue
Maximum operating pressure1,200 psi (8.3 MPa)Feed pH, continuous2–11
Maximum feed temperature113°F (45°C)Feed pH during chemical cleaning1–13
Maximum feed SDI5Maximum pressure drop per element15 psi (0.1 MPa)
Maximum residual chlorine<0.1 ppm

SY-BW brackish-water elements

SY-BW brackish-water elements
ModelAverage fluxStable desalinationEffective areaFeed screen
SY-BW4040-LP2,400 GPD99.5%85 ft² (8 m²)31 mil
SY-BW4040-CHR2,400 GPD99.2%85 ft² (8 m²)31 mil
SY-BW8040-LP(400)10,500 GPD99.5%400 ft² (37 m²)31 mil
SY-BW8040-LP(440)11,500 GPD99.5%440 ft² (41 m²)28 mil
SY-BW8040-FR(400)11,000 GPD99.7%440 ft² (41 m²)34 mil
SY-BW8040-FRB(400)10,500 GPD99.2%400 ft² (37 m²)34 mil
SY-BW8040-FRZ(400)10,500 GPD99.7%400 ft² (37 m²)34 mil

Test: 25°C (77°F), 2,000 ppm NaCl, 225 psi (1.55 MPa), recovery 15%, pH 7.5–8.0. Test-condition flux is the manual’s average permeate flow for that element. Allowable variation on a single element is ±15%. Stated duty: surface water and brackish water with TDS below 8,000 ppm.

SY-BW maximum operating values

SY-BW maximum operating values
LimitValueLimitValue
Maximum operating pressure600 psi (4.1 MPa)Feed pH, continuous2–11
Maximum feed temperature113°F (45°C)Feed pH during chemical cleaning1–13
Maximum feed SDI5Maximum pressure drop per element15 psi (0.1 MPa)
Maximum residual chlorine<0.1 ppm

SY-ULP low-pressure elements

SY-ULP low-pressure elements
ModelAverage fluxStable desalinationEffective areaFeed screen
SY-ULP4040-FR2,600 GPD99.5%85 ft² (8 m²)28 mil
SY-ULP4040-CHR2,600 GPD99.0%76 ft² (7.2 m²)34 mil
SY-ULP4040-LHF2,600 GPD99.0%76 ft² (7.2 m²)34 mil
SY-ULP8040-FR(400)10,500 GPD99.5%400 ft² (37 m²)34 mil
SY-ULP8040-FR(440)11,500 GPD99.5%440 ft² (41 m²)28 mil
SY-ULP8040-CHR(400)10,500 GPD99.0%400 ft² (37 m²)34 mil

Test: 25°C (77°F), 1,500 ppm NaCl, 150 psi (1.03 MPa), recovery 15%, pH 7.5–8.0. Test-condition flux is the manual’s average permeate flow for that element. Allowable variation on a single element is ±15%. Stated duty: feed TDS below 2,000 ppm. The manual cites high water production at an operating pressure of 10 kg.

SY-ULP maximum operating values

SY-ULP maximum operating values
LimitValueLimitValue
Maximum operating pressure600 psi (4.1 MPa)Feed pH, continuous2–11
Maximum feed temperature113°F (45°C)Feed pH during chemical cleaning1–13
Maximum feed SDI5Maximum pressure drop per element15 psi (0.1 MPa)
Maximum residual chlorine<0.1 ppm

How the series is used

  • Duties include brackish desalting, seawater duty where SY-SW is the right series, industrial pure water, tertiary reuse, and a membrane step inside a zero-liquid-discharge train when the water justifies it.
  • Recovery, flux, and rejection are properties of a model at a stated test condition. They are not given as a single catalogue promise.
  • UF or another pretreatment is selected with the element. Send salinity, temperature, and the required permeate quality.

What to send with the quotation

  • Wastewater type and any discharge or reuse standard you must meet.
  • Design capacity in m³/d, and whether the flow is steady or seasonal.
  • Temperature, suspended solids, and, for NF or RO, salinity.
  • Whether you need modules only, a packaged plant, or a system package with commissioning.
Request a technical quotation

Related