Reinforced hollow-fiber ultrafiltration

Hollow-fiber UF modules for clarification, pretreatment, and tertiary duty. External and submerged series are both in the 2025 manual, with operating and CIP tables.

Shuiyan hollow-fiber ultrafiltration elements

Reinforced hollow-fiber UF — operating parameters

Reinforced hollow-fiber UF — operating parameters
ItemPublished value
Typical flux, municipal wastewater (good biodegradability)18–25 LMH
Typical flux, industrial wastewater (good biodegradability)15–18 LMH
Typical flux, general industrial wastewater12–15 LMH
Typical flux, poor biodegradability8–12 LMH
TMP range0–35 kPa
Maximum TMP during filtration35 kPa
Tolerable sludge concentration5,000–12,000 mg/L
Operating mode7 min on, 1 min off
Air scouring intensity80–120 Nm³/(m²·h)
Operating temperature10–35°C
Maintenance sodium hypochlorite washOnce a week, low concentration
Maintenance cleaning duration30–60 min
Maintenance cleaning flow2–4 L per m² of membrane
Maintenance hypochlorite concentration500–800 ppm
Restorative cleaningHypochlorite wash monthly; acid wash at least every six months
Restorative duration2–6 h
Restorative hypochlorite1,000–3,000 ppm
Restorative citric or oxalic acid1–2% by mass
Offline cleaningWhen online cleaning does not restore TMP, or TMP exceeds 35 kPa
Offline duration1–2 days
Offline hypochlorite3,000 ppm
Offline citric or oxalic acid1–2% by mass

Average pore size is less than 0.02 μm. The manual states bacterial removal above 99.99%, and that the product has passed NSF (National Sanitation Foundation) product testing and certification and holds the relevant health permits. No certificate number is printed in the manual. Adjust cleaning to the water and the process.

External UF modules SY-UF

External UF modules SY-UF
SY-UF-40SY-UF-60SY-UF-70
Average pore size0.02 μm0.02 μm0.02 μm
Membrane area40 m²60 m²70 m²
Fiber inner / outer diameter0.7 / 1.3 mm0.7 / 1.3 mm0.7 / 1.3 mm
Effective fiber length1,600 mm1,600 mm1,600 mm
Module dimensionsΦ60 × 2,209 mmΦ225 × 2,168 mmΦ238 × 2,128 mm
Membrane fiberPVDFPVDFPVDF
Sealing compoundEpoxy resinEpoxy resinEpoxy resin
HousingUPVCUPVCUPVC
Maximum inlet pressure0.30 MPa0.30 MPa0.30 MPa
Operating temperature5–40°C5–40°C5–40°C
pH range2–122–122–12
Maximum inlet turbidity300 NTU300 NTU300 NTU
Treated-water turbidity≤0.1 NTU≤0.1 NTU≤0.1 NTU
Operating modeCross-flow or dead-endCross-flow or dead-endCross-flow or dead-end

The same model can be assembled with a different module count.

External UF — design and cleaning

External UF — design and cleaning
ItemPublished value
Typical flux50–100 LMH
TMP range30–150 kPa
Maximum TMP during filtration200 kPa
Maximum feed water pressure300 kPa
Cross-flow recirculation10–30%
Backwash methodAir-water backwash
Design backwash frequency48 times/day
Backwash air pressure≤150 kPa
Backwash gas flow8–12 Nm³/h
Backwash water flow0.5–1.5 times product water flux
Backwash interval30–60 min
Maintenance chemicalCirculating rinse, low-concentration citric acid or sodium hypochlorite
Maintenance duration50 min
Maintenance frequency1–3 days per set
Maintenance citric-acid frequency1–3 days per set
Maintenance flow1–2 m³ per module
Maintenance concentration300–500 ppm
Restorative methodCirculating rinse, high-concentration citric acid and sodium hypochlorite
Restorative duration90–120 min
Restorative frequency30–90 days per cycle
Restorative flow1–3 m³ per module
Restorative concentration1,000–3,000 ppm

Immersed UF modules SY-SUF

Immersed UF modules SY-SUF
SY-SUF-17SY-SUF-22SY-SUF-32
Average pore size0.02 μm0.02 μm0.02 μm
Membrane area17 m²22 m²32 m²
Fiber inner / outer diameter1.6 / 2.0 mm1.6 / 2.0 mm1.0 / 2.0 mm
Overall dimensions535 × 40 × 1,500 mm535 × 40 × 2,000 mm844 × 49 × 2,091 mm
Membrane fiberPVDFPVDFPVDF
EncapsulantEpoxy resinEpoxy resinEpoxy resin
ConfigurationSubmergedSubmergedSubmerged
Filtration directionOutside-inOutside-inOutside-in
Maximum suction pressure65 kPa65 kPa65 kPa
Maximum operating temperature40°C40°C40°C
pH range2–122–122–12
Turbidity of treated water<0.1 NTU<0.1 NTU<0.1 NTU

Design flux is set from water temperature and water quality. Fiber tensile strength is stated as above 100 N.

Immersed UF — design and cleaning

Immersed UF — design and cleaning
ItemPublished value
Typical flux20–60 LMH
TMP range0–65 kPa
Maximum TMP during filtration65 kPa
Water recovery>95%
Permeate turbidity<0.1 NTU
Backwash methodAir-water backwash
Design backwash frequency60–120 min/cycle
Backwash gas flow4.5–6 Nm³/h per module
Backwash water flow1–2 times the permeate flux
Backwash operation55–115 min, then air-water backwash for 1–2 min, drain and air purge for 1 min
Maintenance hypochlorite frequencyEvery 1–5 days
Maintenance flow44–88 L per cycle per module
Maintenance concentration300–1,000 ppm
Maintenance methodSoaking, circulation, aeration
Maintenance duration2–4 hours, including chemical injection and drainage
Acid or citric cleaningEvery 7–30 days
Hypochlorite restorative frequencyEvery 7–30 days
Minimum chemical volumeEnough to submerge the modules
Restorative concentrationHydrochloric acid, pH 2; citric acid 0.5–1%; sodium hypochlorite 500–1,500 ppm
Offline cleaning1–2 times per year, 1–10 h
Offline chemicalsHydrochloric acid pH 2; citric acid 1–2%; sodium hypochlorite 3,000–5,000 ppm

How the series is used

  • Duties include surface-water and groundwater clarification, pretreatment ahead of ion exchange or reverse osmosis, and tertiary polishing.
  • The manual prints operating limits and a CIP table for this section. Those limits are quoted with the model, not averaged across the catalogue.
  • Send turbidity or suspended solids, temperature, and the downstream membrane if this UF is a pretreatment.

What to send with the quotation

  • Wastewater type and any discharge or reuse standard you must meet.
  • Design capacity in m³/d, and whether the flow is steady or seasonal.
  • Temperature, suspended solids, and, for NF or RO, salinity.
  • Whether you need modules only, a packaged plant, or a system package with commissioning.